Description
Product Overview:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Technical Specifications:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Parameter Name | Parameter Value |
---|---|
Product Model | WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004 |
Manufacturer | Woodward |
Product Type | Digital Burner Management Module |
Power Supply | 12–24 VDC ±10% |
Physical Dimensions | 229 mm (W) × 178 mm (H) × 102 mm (D) |
Weight | 1.5 kg |
Communication Interfaces | Ethernet (10/100 Mbps), Modbus RTU, RS-485 |
I/O Channels | 16 digital inputs, 8 digital outputs, 8 analog inputs, 4 analog outputs |
Operating Temperature | -40°C to +85°C |
Vibration Resistance | 5–50 Hz, 2 g (IEC 60068-2-6) |
Certifications | CE, UL, EN 50155, API 614, CSA |
Fuel Types Supported | Natural gas, diesel, heavy fuel oil |

WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Main Features and Advantages:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004

WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Application Areas:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
-
Power Generation:
- Gas Turbine Generators: Manages combustion in combined cycle power plants, ensuring efficient energy conversion and grid stability. Controls load-sharing between multiple turbines and executes emergency shutdown protocols during fault conditions.
- Steam Boilers: Optimizes fuel combustion in industrial boilers, reducing energy waste and maintaining consistent steam output for manufacturing processes.
-
Oil & Gas:
- Process Heaters: Controls burners in refinery furnaces and pipeline heating systems, ensuring uniform temperature distribution and compliance with emission regulations.
- Offshore Platforms: Provides fail-safe burner management for gas compression systems, withstanding salt fog, high winds, and other harsh marine conditions.
-
Industrial Heating:
- Steel and Aluminum Production: Manages reheating furnaces by precisely controlling fuel flow and air intake, improving metal processing efficiency and reducing scrap rates.
- Chemical Plants: Ensures safe operation of ethylene crackers and reformers, with real-time monitoring of flame stability and rapid response to process upsets.
-
Marine Propulsion:
- Marine Engines: Controls auxiliary burners in shipboard power systems, supporting dynamic load adjustments during navigation and port operations.
Related Products:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
- WOODWARD BUM60-1224-54-B-002-VC-A0: A higher-power variant with additional analog channels, designed for multi-burner systems in large power plants.
- WOODWARD 8290-1234: A speed control module that integrates with the BUM60-1224 series to provide closed-loop speed regulation for gas engines.
- WOODWARD 3501E: A digital engine control unit (DECU) for diesel engines, often used alongside the BUM60-1224 in hybrid power systems.
- WOODWARD 9907-123: A flame detector module compatible with the BUM60-1224, providing reliable flame supervision for safety-critical applications.
- WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G002: A legacy version with basic I/O configuration, suitable for retrofitting older burner systems.
WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Installation and Maintenance:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Before installing the WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004, ensure the following:
- Verify the power supply voltage (12–24 VDC) and ground the control panel to minimize electromagnetic interference.
- Use Woodward’s ProView software to configure I/O channels, ignition timing, and safety parameters based on the specific burner design.
- Mount the module on a DIN rail in a well-ventilated enclosure, allowing at least 50 mm of clearance for heat dissipation.
- Routine Checks: Inspect module LEDs monthly to confirm power, communication, and operational status. Replace faulty I/O modules promptly to avoid system downtime.
- Software Updates: Periodically update firmware via the Ethernet interface to access new features and security patches, ensuring compatibility with evolving industry standards.
- Sensor Calibration: Annually calibrate connected sensors (e.g., pressure transmitters, thermocouples) using certified equipment to maintain measurement accuracy.
- Environmental Cleaning: Clean dust and debris from the module’s vents every six months, particularly in dusty environments, to prevent overheating and ensure reliable operation.
WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Product Warranty:WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000 3522-1004
Whatsapp: +86 18859254943
E-mail: sales@ygplc.com
Woodward 8237-1369 Pulse input (PI) module
Woodward 8237-1600 Digital input module
WOODWARD 9907-1200 Digital 24VDC output module
WOODWARD 8200-1302 Digital output module 24VDC
WOODWARD 8273-140 Output module
Woodward 8237-1600 High density main box
WOODWARD 5453-277 Remote extender module
WOODWARD 5453-279 Input pulse module
GE IS220PAICH1B Power strip
GE IS220PDOAH1A Power source
GE IS200TSVCH1AED Tachometer sensor
GE SR469 469-P5-HI-A20-E Communication input interface component
GE SR469 469-P5-HI-A20-E RXM rack