WOODWARD 5466-1156 | MicroNet TMR 48/24 HDDIO-2 Smart-Plus Digital I/O Module Woodward

$4,200.00

The WOODWARD 5466-1156 is a MicroNet TMR 48/24 HDDIO-2 Smart-Plus module intended for redundant turbine and engine control applications.
Brand model:WOODWARD 
Product Name:5466-1156
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Category: Brand:

Description

Product Overview

The WOODWARD 5466-1156 is a MicroNet TMR 48/24 HDDIO-2 Smart-Plus module intended for redundant turbine and engine control applications. It provides 48 discrete inputs and 24 discrete outputs, giving the controller a high-density interface for status signals, permissives, alarms, trips, and relay commands. Woodward identifies this version as a backward-compatible spare for older MicroNet TMR HDD applications using Coder 4.06. It is specifically intended for TMR installations rather than being a general-purpose I/O card.

The input circuits are optically isolated, while the associated field termination arrangement supports 24 VDC discrete signals. Outputs can interface with compatible relay modules through the specified FTM and cable arrangement. The module does not require field calibration or potentiometer adjustment. For maintenance teams, the practical concern is compatibility: firmware/Coder revision, TMR architecture, FTM type, and replacement status should all be checked before installation.

Technical Specifications — 5466-1156

Parameter Value
Product Model 5466-1156
Manufacturer Woodward
Product Type MicroNet TMR 48/24 HDDIO-2 Smart-Plus Digital I/O Module
Series MicroNet TMR
Discrete Inputs 48 channels
Discrete Outputs 24 channels
Input Type Optically isolated discrete input
Typical Input Threshold 8 VDC at 1.5 mA = OFF; >16 VDC at 3 mA = ON
Field Interface 24 VDC 48/24 or compatible discrete FTM configuration
Output Update Time 5 ms
Input Update Time 5 ms
Isolation 500 VDC to earth ground; 1,000 VDC to control common
Contact Supply Isolated 24 VDC, up to 400 mA
Time Stamping 500 μs resolution
Operating Temperature 0 to +55 °C
Storage Temperature −40 to +105 °C
Calibration Not required
Mounting MicroNet chassis card slot
Application TMR redundant control systems

The electrical values above are taken from Woodward MicroNet documentation; actual field configuration depends on the installed FTM and system architecture.

WOODWARD 5466-1156

WOODWARD 5466-1156

Key Features and Benefits — 5466-1156

  • 48 discrete input channels and 24 discrete output channels.
  • Designed for MicroNet TMR redundant control architectures.
  • Optical isolation helps separate field discrete signals from control electronics.
  • Supports 24 VDC discrete field termination arrangements.
  • 5 ms I/O update performance is suitable for turbine-control sequencing and discrete protection logic.
  • No calibration potentiometers are required.
  • Backward-compatible spare for selected legacy MicroNet TMR HDD applications.
  • Appropriate for applications requiring replacement of older HDD module functionality.

Related Models

5466-1158: Simplex 48/24 HDDIO-2 Smart-Plus module intended for MicroNet Simplex applications and backward-compatible Coder 4 systems.

5466-1051: MicroNet TMR 48/24 HDDIO Smart-Plus module for newer implementations; Woodward identifies it as the preferred replacement architecture for systems using Coder 5.04 or later.

5453-276: Relay/field termination component used with the relevant MicroNet discrete I/O configuration.

Installation and Maintenance — 5466-1156

The module slides into the MicroNet chassis card guides and connects to the motherboard. Secure the card using the upper and lower retaining screws after confirming connector alignment. The applicable FTM configuration must match the wiring arrangement and cable set specified by Woodward.

Before replacement, record the existing module part number, revision, Coder version, FTM configuration, and field wiring. Pay particular attention to whether the system is operating with legacy Coder 4.06 compatibility or a newer Smart-Plus implementation. Woodward specifically distinguishes the replacement parts by Coder generation, so part-number substitution should not be made solely from physical appearance.

Personally, I would treat revision control as the first inspection point on this part. A visually identical I/O module can still be the wrong spare when the controller software generation or TMR configuration differs.

Product Warranty — 5466-1156

Warranty coverage depends on the supplier and condition of the unit, such as new, unused surplus, refurbished, or tested spare stock. Procurement records should include the exact part number, hardware revision, serial number, test status, and applicable return terms.

The WOODWARD 5466-1156 is best classified as a MicroNet TMR 48/24 HDDIO-2 Smart-Plus digital I/O spare, particularly relevant to legacy redundant control systems requiring backward-compatible discrete I/O functionality.

WOODWARD 5453-279 | Speed Control Module | 5466-425
WOODWARD 5466-258 | Electronic governor module | 5501-471
WOODWARD 5466-318 | Speed control module | 5466-425
WOODWARD 5466-425 | Turbine Speed Control Module | 5501-381
WOODWARD 5501-381 | Digital engine control module | 8406-113
WOODWARD 5501-470 | Digital Turbine Controller | 5466-318
WOODWARD 5501-471 | Electronic governor module | 5453-759