Sale!

TRICONEX 3311S2 | Digital Input Module | 3401 TRICONEX

Original price was: $5,500.00.Current price is: $5,036.00.

The TRICONEX 3311S2 is a digital input module designed specifically for safety instrumented systems (SIS) in industrial automation.

Brand model:TRICONEX
Product Name:3311S2
Warranty: 1 year
Weight:1.6kg
Origin:USA
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Category: Brand:

Description

Product Overview

The TRICONEX 3311S2 is a digital input module designed specifically for safety instrumented systems (SIS) in industrial automation. It serves as a critical link between field devices—such as sensors, switches, and relays—and the central controller, collecting real-time status signals to support safety-critical decision-making. As part of TRICONEX’s trusted lineup of I/O modules, the 3311S2 is engineered to integrate seamlessly with TRICONEX Tricon and TriconEX systems, which use triple modular redundancy (TMR) to ensure reliability.

 

The TRICONEX 3311S2 stands out for its ability to handle diverse input signals while maintaining high accuracy, even in harsh industrial environments. Its design prioritizes fault tolerance, making it a key component in systems that need to meet strict safety standards like SIL 3. By reliably transmitting critical data from the field to the controller, the 3311S2 helps prevent accidents, reduce downtime, and keep industrial operations running smoothly. Whether in a chemical plant or an oil refinery, this module ensures that the system always has access to accurate, up-to-date information.

Technical Specifications

Product model 3311S2
Manufacturer TRICONEX
Product type Digital Input Module
Input voltage 24V DC ±10%
Number of channels 16 isolated channels
Signal type Dry contact, 24V DC logic signals
Electrical isolation 2500Vrms between channels and system ground
Response time <10ms
Physical dimensions 130mm (W) x 160mm (H) x 210mm (D)
Weight 1.1 kg
Interface type Screw terminal block
Working environment Operating temperature: -40°C to +70°C; Relative humidity: 5% to 95% (non-condensing)
Place of origin United States
Safety compliance SIL 3 (IEC 61508), ISA S84.01
3311S2

3311S2

Related products

  • TRICONEX 3301: A digital input module similar to 3311S2 but with 32 channels, designed for larger systems needing to monitor more field devices at once.
  • TRICONEX 3008X: A digital output module that works with 3311S2 to form a complete input-output loop, sending control signals to valves or relays based on data from 3311S2.
  • TRICONEX 4351B: The main processor module in TRICONEX Tricon systems. It uses signals from 3311S2 to execute safety logic, such as triggering emergency shutdowns.
  • TRICONEX 8312: A redundant power supply module that provides stable 24V DC to 3311S2, ensuring the input module keeps working even if the primary power source fails.
  • TRICONEX 3625: A digital input module with 32 channels, serving as an alternative to 3311S2 in applications requiring more monitoring points.
  • TRICONEX 9662-810: A communication module that shares data from the controller—including signals collected by 3311S2—with external systems like SCADA, enabling remote monitoring.
  • TRICONEX 7400: A power distribution unit that delivers power to multiple modules, including 3311S2, in large installations, simplifying wiring and power management.

Main features and advantages

High reliability: The 3311S2 uses 2500Vrms electrical isolation between its channels and the system ground. This isolation blocks electrical noise and surges, which are common in factories, refineries, and power plants. It ensures that the signals sent to the controller are accurate, reducing the risk of false alarms or missed warnings.

 

Compatibility with TMR systems: The module is designed for TRICONEX’s triple modular redundancy (TMR) architecture. In TMR systems, three separate channels check each other’s work. This means the 3311S2 can keep operating even if one channel fails, making it ideal for safety-critical applications that need to meet SIL 3 standards.

 

Fast response: With a response time of less than 10ms, the 3311S2 quickly detects changes in field device statuses. This speed is crucial in emergencies—for example, if a pressure sensor in an oil pipeline detects a spike, the module sends this info to the controller without delay, allowing a quick shutdown.

 

Easy to install and maintain: The 3311S2 uses a screw terminal block for wiring, which is simple to connect without special tools. It also has status lights that show if each channel is working, making it easy for maintenance teams to spot issues like loose wires or faulty sensors.

 

Durable design: Built to handle tough conditions, the module works in temperatures from -40°C to +70°C and resists humidity. This durability ensures it performs reliably in outdoor installations, like offshore oil rigs, or in hot environments, such as chemical reactors.

3311S2

3311S2

Installation and maintenance

Pre-installation preparations: Before installing 3311S2, check that it fits the target TRICONEX chassis, such as TriconEX main racks. Confirm the input voltage matches the 24V DC requirement. Make sure the mounting area has enough space for wiring and airflow to prevent overheating. Turn off the system power and disconnect all field wires to avoid electrical damage. Inspect the module for cracks or bent pins before putting it in the chassis.

 

Maintenance suggestions: For 3311S2, check the terminal block connections every three months to ensure they are tight and free of corrosion. Use a multimeter to verify that input signals from field devices reach the module correctly. Clean dust from the module’s surface and vents regularly to keep it cool. Watch the status lights—if a light stays off when it should be on, check the connected sensor or wiring. In systems with two 3311S2 modules (for backup), test the failover function once a year to ensure the backup takes over smoothly if the main module fails.

Application fields

The TRICONEX 3311S2 is widely used in industries where safety monitoring is essential. In the oil and gas sector, it monitors signals from pressure switches, flame detectors, and valve position sensors on offshore rigs and refineries. For example, if a flame detector near a storage tank detects a fire, the 3311S2 sends this signal to the controller, which triggers an emergency shutdown to prevent explosions.

 

In chemical processing plants, the 3311S2 collects data from temperature sensors and level switches in reactors. This data helps the SIS ensure that chemicals are mixed and heated within safe limits, preventing spills or reactions that could release harmful substances.

 

In power generation facilities, the module monitors status signals from turbine sensors and generator breakers. If a turbine vibrates too much, the 3311S2 quickly sends this info to the controller, which can slow or stop the turbine to avoid damage.

 

In all these fields, the TRICONEX 3311S2 acts as a reliable bridge between field devices and the safety system, ensuring that critical information is always available when needed.

3311S2

3311S2

Product guarantee

Our company offers a one-year quality warranty service for 3311S2, covering hardware malfunctions not caused by human factors. During the warranty period, if the product shows abnormal performance or functional failure, we will provide replacement services. In addition, for discontinued models or urgent demands, relying on our global supply chain network, we can quickly respond to customers’ procurement needs for scarce spare parts, and provide reliable services to support the continuous and stable operation of industrial systems. Our company is a leading enterprise in the industrial control industry, established in 2007, with 17 years of experience. We are an import and export trade distribution company, mainly selling major brands of industrial control parts, with many unpopular discontinued models and a large stock. Our company has the advantage of supply channels, with a large number of spot items to meet the needs of customers anxious to find spare parts.