The SST 5136-PFB-VME is a VMEbus interface card that connects a VME-based host computer, motion controller, or programmable controller to PROFIBUS networks. It supports PROFIBUS DP Master, DP Slave, and FDL Layer 2 communication, with these operating modes capable of running simultaneously. The card uses an onboard Intel i960 processor to handle PROFIBUS protocol processing and data exchange with the host through shared memory. Standard PROFIBUS baud rates from 9.6 Kbaud through 12 Mbaud are supported, making the interface suitable for legacy industrial automation systems that rely on VMEbus computing platforms. The hardware provides onboard RAM and flash storage for application software and PROFIBUS configuration data. Personally, I would treat this as a legacy communication component and verify the host VME architecture, driver version, firmware, and configured network role before replacement.
Technical Specifications — 5136-PFB-VME
| Parameter | Value |
|---|---|
| Product Model | 5136-PFB-VME |
| Manufacturer | SST / Woodhead |
| Product Type | PROFIBUS VME Interface Card |
| Processor | Intel i960 32-bit processor |
| Local RAM | 512 KB |
| Shared RAM | 256 KB |
| Flash Memory | 512 KB |
| PROFIBUS Function | DP Master, DP Slave, FDL Layer 2 |
| PROFIBUS Baud Rate | 9.6 Kbaud to 12 Mbaud |
| VME Interface | 6U, P1 compatible, IEEE 1014 |
| Addressing | Standard and short address spaces |
| Power | Maximum 950 mA at +5 VDC |
| Operating Temperature | 0 to +60°C |
| Mounting | VMEbus chassis |
| Typical Interfaces | PROFIBUS DB-9, VMEbus, serial configuration port |
| Compliance | CISPR 22; PROFIBUS certification not listed |
The hardware guide specifies the 6U VME format, 512 KB local RAM, 256 KB shared RAM, 512 KB flash memory, maximum 950 mA at 5 VDC, and an operating range of 0 to 60°C.

SST 5136-PFB-VME
Key Features and Benefits — 5136-PFB-VME
- Supports PROFIBUS DP Master and DP Slave operation.
- Provides FDL Layer 2 messaging capability.
- Supports standard PROFIBUS speeds up to 12 Mbaud.
- Onboard processor reduces protocol-processing load on the VME host.
- Shared memory provides a direct data exchange mechanism with host applications.
- Flash memory stores firmware and PROFIBUS configuration data.
- Designed for industrial VME-based control and computing platforms.
Related Models
5136-PFB-PCI: PCI-based PROFIBUS interface for industrial computers using PCI rather than VMEbus.
5136-DN-VME: VMEbus interface variant intended for DeviceNet networks.
PB3-VME: Later SST VME-based PROFIBUS interface family designed for newer industrial architectures.
SST PROFIBUS DP Interface Cards: Related communication products providing PROFIBUS connectivity through different host-bus architectures.
Installation and Maintenance — 5136-PFB-VME
Before installation, verify the VME chassis slot, address-switch configuration, memory mapping, interrupt settings, and PROFIBUS network parameters. The card requires its PROFIBUS software module and appropriate configuration before normal network operation; configuration can be loaded through the serial port or from host software.
During maintenance, inspect the VME edge connector, PROFIBUS connector, jumpers, switches, and configuration-port connection. Confirm that firmware and configuration data correspond to the existing host application. For legacy systems, keeping a backup of the working configuration is particularly valuable because software compatibility can be as important as the hardware itself.
Product Warranty — 5136-PFB-VME
Warranty coverage depends on the supplier and unit condition, including new, unused surplus, refurbished, or repaired stock. Before procurement, confirm functional-test status, firmware revision, serial-number traceability, warranty period, and return conditions.
The SST 5136-PFB-VME is a specialized legacy PROFIBUS interface for VMEbus systems. Exact compatibility should be confirmed at the hardware, firmware, driver, and network-configuration levels before replacement.