HONEYWELL FC-DCOM-232/485 | RS-232 and RS-485 Interface Honeywell

Honeywell FC-DCOM-232/485 is a communication interface Field Termination Assembly (FTA) used with the Honeywell Safety Manager platform.
Brand model:HONEYWELL 
Product Name:FC-DCOM-232/485
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Category: Brand:

Description

  • Model: FC-DCOM-232/485
  • Brand: Honeywell
  • Series: Safety Manager
  • Core Function: Provides serial communication interfaces for safety systems
  • Type: Communication Interface Field Termination Assembly
  • Key Specs: 1 × RS-232; 2 × RS-485/422; 5 VDC ±5%; up to 2 MBaud

Product Introduction

Honeywell FC-DCOM-232/485 is a communication interface Field Termination Assembly (FTA) used with the Honeywell Safety Manager platform. Honeywell’s safety certification documentation identifies it specifically as a communication interface FTA for RS-232 and RS-485, with a conformal-coated version listed under the same family.

The module provides one RS-232 interface and two RS-485/422 interfaces, allowing Safety Manager equipment to communicate with compatible serial devices. Published technical data specifies 5 VDC ±5% supplied by the control processor, RS-232 operation up to 250 kBaud, and RS-485/422 operation up to 2 MBaud.

Key Technical Specifications

Parameter Specification
Model FC-DCOM-232/485
Manufacturer Honeywell
Product Family Safety Manager
Product Type Communication Interface FTA
RS-232 Ports 1
RS-485/422 Ports 2
RS-232 Standard EIA/TIA-232
RS-232 Baud Rate 0–250 kBaud
RS-485/422 Standard EIA/TIA-485-A
RS-485/422 Baud Rate 0–2 MBaud
Input Voltage 5 VDC ±5%
Maximum Input Current 500 mA
Power Source Control processor
Mounting DIN EN TS32 / TS35 × 7.5 rail
Dimensions 110 × 70 × 61 mm
Approvals CE, TÜV, UL, FM

The published specifications are notably different from some generic online descriptions that incorrectly assign 12–48 VDC or 220 VAC input to this part. For procurement, the 5 VDC ±5% control-processor supply specification should be treated as the relevant value.

HONEYWELL FC-DCOM-232/485

HONEYWELL FC-DCOM-232/485

Application and Selection Notes

The FC-DCOM-232/485 is intended for Honeywell Safety Manager communication architectures, particularly installations that need serial connectivity to compatible external equipment.

RS-232 is generally suited to point-to-point communication. RS-485/422 is more appropriate where longer serial links or multi-device communication are required. The module’s documented interface speeds extend to 2 MBaud on RS-485/422, although actual cable length depends on baud rate and communication mode.

This is not an Ethernet communication card. Nor should it be treated as a generic RS-232/RS-485 converter. Its power arrangement, Safety Manager integration, and approved system architecture matter.

Replacement Pitfalls

Power supply: The interface receives 5 VDC ±5% from the control processor. Do not connect an external 24 VDC supply based on assumptions from generic serial converters.

Port assignment: Check whether the existing installation uses RS-232, RS-485, or RS-422 before replacement.

Baud rate: Up to 250 kBaud is specified for RS-232, while RS-485/422 supports up to 2 MBaud. Higher speed does not automatically mean longer cable distance.

Conformal coating: Honeywell safety documentation identifies a conformal-coated version. If the existing installation requires that environmental protection, verify the exact revision and coating designation.

Grounding: The communication interface requires proper protective earth/shield grounding for the field communication wiring.

Personally, I would photograph every serial connection and its terminal assignment before removing the old unit. RS-485 polarity and termination errors are simple to make and surprisingly time-consuming to trace.

Quality Inspection and Testing

  1. Inbound inspection: Verify model, revision, serial number, terminals, connectors, DIN-rail mechanism, and conformal-coating condition where applicable.
  2. Live test: Power the unit from a compatible Safety Manager control processor and verify startup and communication-interface status.
  3. RS-232 test: Establish a controlled serial connection and verify communication at representative baud rates.
  4. RS-485/422 test: Verify transmission and reception using a suitable test device and confirm the configured wiring mode.
  5. Electrical testing: Check supply input, grounding continuity, and applicable isolation parameters.
  6. Final QC: Record test results, photograph the unit, apply ESD protection, and package the module securely.

Test reports, photographs, and available test video can be supplied when available.

Warranty and Availability

Condition: Confirm whether the unit is New Original (New Surplus), used, or refurbished.

Availability: FC-DCOM-232/485 is a legacy Safety Manager component, so actual warehouse stock and revision should be confirmed before purchase.

Lead Time: Subject to physical stock, inspection, packaging, and export processing.

Warranty: Supplier warranty applies according to the agreed commercial terms.

The HONEYWELL FC-DCOM-232/485 is a Safety Manager-specific serial communication interface rather than a general-purpose converter. For international procurement, verify the exact revision, port configuration, control-processor compatibility, conformal-coating requirement, condition, country of origin, and export documentation before shipment.