Description
- Model: FC-DCOM-232/485
- Brand: Honeywell
- Series: Safety Manager
- Core Function: Provides serial communication interfaces for safety systems
- Type: Communication Interface Field Termination Assembly
- Key Specs: 1 × RS-232; 2 × RS-485/422; 5 VDC ±5%; up to 2 MBaud
Product Introduction
Honeywell FC-DCOM-232/485 is a communication interface Field Termination Assembly (FTA) used with the Honeywell Safety Manager platform. Honeywell’s safety certification documentation identifies it specifically as a communication interface FTA for RS-232 and RS-485, with a conformal-coated version listed under the same family.
The module provides one RS-232 interface and two RS-485/422 interfaces, allowing Safety Manager equipment to communicate with compatible serial devices. Published technical data specifies 5 VDC ±5% supplied by the control processor, RS-232 operation up to 250 kBaud, and RS-485/422 operation up to 2 MBaud.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Model | FC-DCOM-232/485 |
| Manufacturer | Honeywell |
| Product Family | Safety Manager |
| Product Type | Communication Interface FTA |
| RS-232 Ports | 1 |
| RS-485/422 Ports | 2 |
| RS-232 Standard | EIA/TIA-232 |
| RS-232 Baud Rate | 0–250 kBaud |
| RS-485/422 Standard | EIA/TIA-485-A |
| RS-485/422 Baud Rate | 0–2 MBaud |
| Input Voltage | 5 VDC ±5% |
| Maximum Input Current | 500 mA |
| Power Source | Control processor |
| Mounting | DIN EN TS32 / TS35 × 7.5 rail |
| Dimensions | 110 × 70 × 61 mm |
| Approvals | CE, TÜV, UL, FM |
The published specifications are notably different from some generic online descriptions that incorrectly assign 12–48 VDC or 220 VAC input to this part. For procurement, the 5 VDC ±5% control-processor supply specification should be treated as the relevant value.

HONEYWELL FC-DCOM-232/485
Application and Selection Notes
The FC-DCOM-232/485 is intended for Honeywell Safety Manager communication architectures, particularly installations that need serial connectivity to compatible external equipment.
RS-232 is generally suited to point-to-point communication. RS-485/422 is more appropriate where longer serial links or multi-device communication are required. The module’s documented interface speeds extend to 2 MBaud on RS-485/422, although actual cable length depends on baud rate and communication mode.
This is not an Ethernet communication card. Nor should it be treated as a generic RS-232/RS-485 converter. Its power arrangement, Safety Manager integration, and approved system architecture matter.
Replacement Pitfalls
Power supply: The interface receives 5 VDC ±5% from the control processor. Do not connect an external 24 VDC supply based on assumptions from generic serial converters.
Port assignment: Check whether the existing installation uses RS-232, RS-485, or RS-422 before replacement.
Baud rate: Up to 250 kBaud is specified for RS-232, while RS-485/422 supports up to 2 MBaud. Higher speed does not automatically mean longer cable distance.
Conformal coating: Honeywell safety documentation identifies a conformal-coated version. If the existing installation requires that environmental protection, verify the exact revision and coating designation.
Grounding: The communication interface requires proper protective earth/shield grounding for the field communication wiring.
Personally, I would photograph every serial connection and its terminal assignment before removing the old unit. RS-485 polarity and termination errors are simple to make and surprisingly time-consuming to trace.
Quality Inspection and Testing
- Inbound inspection: Verify model, revision, serial number, terminals, connectors, DIN-rail mechanism, and conformal-coating condition where applicable.
- Live test: Power the unit from a compatible Safety Manager control processor and verify startup and communication-interface status.
- RS-232 test: Establish a controlled serial connection and verify communication at representative baud rates.
- RS-485/422 test: Verify transmission and reception using a suitable test device and confirm the configured wiring mode.
- Electrical testing: Check supply input, grounding continuity, and applicable isolation parameters.
- Final QC: Record test results, photograph the unit, apply ESD protection, and package the module securely.
Test reports, photographs, and available test video can be supplied when available.
Warranty and Availability
Condition: Confirm whether the unit is New Original (New Surplus), used, or refurbished.
Availability: FC-DCOM-232/485 is a legacy Safety Manager component, so actual warehouse stock and revision should be confirmed before purchase.
Lead Time: Subject to physical stock, inspection, packaging, and export processing.
Warranty: Supplier warranty applies according to the agreed commercial terms.
The HONEYWELL FC-DCOM-232/485 is a Safety Manager-specific serial communication interface rather than a general-purpose converter. For international procurement, verify the exact revision, port configuration, control-processor compatibility, conformal-coating requirement, condition, country of origin, and export documentation before shipment.