Description
Product Overview
The UFC092BE01 HIEE300910R0001 is an ABB binary input module used in UNITROL power-electronics and excitation-system applications. ABB’s UNITROL P spare-parts documentation identifies the corresponding UFC092 family device as a 16-fold binary input module, with one module typically used in the system. The module receives discrete status signals from field devices and makes those signals available to the control system for monitoring, interlocking, alarm handling, and sequence logic. It is therefore relevant to generator excitation equipment, industrial power-conversion systems, and other ABB automation installations where dependable digital-status acquisition is required.
For maintenance teams, exact identification is important. The full identification number should be checked against the installed hardware and system documentation before replacement, particularly when maintaining legacy UNITROL assemblies. A visually similar I/O board is not necessarily electrically interchangeable.
Technical Specifications — UFC092BE01 HIEE300910R0001
| Parameter | Value |
|---|---|
| Product Model | UFC092BE01 |
| Product ID | HIEE300910R0001 |
| Manufacturer | ABB |
| Product Type | Binary Input Module |
| System / Application | ABB UNITROL excitation and power-electronics systems |
| Digital Inputs | 16 |
| Signal Type | Binary / discrete field signals |
| Power | Application-specific; verify system documentation |
| Communication / Protocol | System-specific I/O interface |
| Operating Temperature | Verify applicable UNITROL system documentation |
| Mounting | Equipment-specific |
| Dimensions (HxWxD) | Verify from equipment documentation |
| Weight | Verify before shipment |
| Typical Interfaces | Field binary input and system I/O connections |
| Compliance | Application and system dependent |
ABB documentation lists the device family as a Binary Input 16 Fold within UNITROL P spare-parts architecture. Supplier technical listings also identify the item as an ABB binary/input module, although detailed electrical parameters should be confirmed against the original application manual rather than relying on reseller specifications.

ABB UFC092BE01 HIEE300910R0001
Key Features and Benefits — UFC092BE01 HIEE300910R0001
- 16-channel binary input architecture for discrete status acquisition.
- Designed for ABB UNITROL-related power-electronics and excitation applications.
- Suitable for monitoring switches, interlocks, permissive signals, alarms, and equipment status.
- Supports maintenance replacement at the module level without redesigning the complete control architecture.
- Useful as a controlled spare for critical excitation-system inventory.
- Full part-number verification helps avoid compatibility problems during field replacement.
- Appropriate ESD precautions should be used when handling the electronic assembly.
In a generator or excitation system, digital inputs often carry operationally important information. A wiring or voltage mismatch can therefore produce more than a simple indication error; it may affect permissives, alarms, or control sequences.
Related Models
UFC092 Series — ABB UNITROL binary-input hardware used for discrete signal acquisition in compatible power-electronics systems.
UP C090 AE1 HIEE300661R0001 — ABB Binary Field Bus Coupler listed alongside the 16-fold binary input module in UNITROL P spare-parts documentation.
AR C093 A1 HIEE300690R0001 — ABB 16-fold output relay module used within the same UNITROL P spare-parts architecture.
UA C096AE1 HIEE300794R0001 — ABB analog input/output module listed as another UNITROL P I/O spare.
Installation and Maintenance — UFC092BE01 HIEE300910R0001
Before installation, isolate the relevant excitation or power-electronics equipment according to the site safety procedure. Record the existing module identification, wiring arrangement, and any configuration information before removal.
Check the replacement assembly for bent connectors, contamination, corrosion, damaged components, and label inconsistencies. Compare the replacement against the removed unit and verify the compatible cabinet or system position. Use ESD-safe handling throughout the procedure.
After installation, verify field wiring and input status channel by channel. Confirm that alarms, permissives, interlocks, and associated control-system indications behave correctly before returning the equipment to normal service. Personally, I would document the original wiring and input-state conditions before touching the module; that record is often useful during commissioning checks.
Product Warranty — UFC092BE01 HIEE300910R0001
Warranty terms depend on the supplier and item condition. Procurement records should identify whether the module is new, unused surplus, refurbished, or previously installed, together with any available inspection or functional-test documentation.
For critical UNITROL spare inventory, retain the complete ABB identification number, serial number where applicable, inspection status, storage history, and equipment compatibility information. This provides useful traceability for future maintenance and replacement planning.