ABB DSMB-02C 64666606 | ACS800 Control Board

$4,355.00

ABB DSMB-02C (64666606) is a control board used in the ABB ACS800-304/704 diode supply unit (DSU) assembly.
Brand model:ABB
Product Name:DSMB-02C
Warranty: 1 year
Origin:Switzerland
Inventory: in stock
HS code:85389000.00
Delivery time: 3-4days/1month
Product status: Original,Brand new

 

Category:

Description

ABB DSMB-02C (64666606) is a control board used in the ABB ACS800-304/704 diode supply unit (DSU) assembly. It provides gate-control signals to the associated thyristor/diode power modules through dedicated cable connections. The board is part of the supply-unit control hardware and works alongside other components in the DSU assembly.

The DSMB-02C is identified by ABB as a control board and is listed as a component of the ACS800DSUV3 kit. Its connections also interface with associated supply-unit circuitry, including auxiliary power and charging-control signals linked to the DSMB-01C board. The documented net weight is 0.3 kg. For replacement planning, confirm the complete part number, installed DSU configuration, board revision, fuse arrangement, and cable connections before selecting or installing a replacement.

Key Technical Specifications

Parameter Specification
Manufacturer ABB
Model DSMB-02C
Product ID 64666606
Common extended part number 3AFE64666606
Product type Control board
Associated drive family ABB ACS800
Documented equipment ACS800-304/704 diode supply units
Related assembly ACS800DSUV3 kit
Primary function Gate control for thyristor/diode power modules
Related control hardware DSMB-01C power supply board
Net weight 0.3 kg
ABB Advant OCS Product Guide

ABB Advant OCS Product Guide

Detailed Product Overview

Role in the ABB ACS800 Diode Supply Unit

The ABB DSMB-02C is a control board installed in the supply-unit assembly of the documented ACS800-304/704 drive configurations. Its primary role is to provide the gate-control signals used by the associated thyristor/diode power modules.

These semiconductor modules form part of the DSU power-conversion hardware. The DSMB-02C connects to them through dedicated gate-control cables, making the board and its associated wiring important elements of the supply-unit control arrangement.

Gate-Control Connections and Power Electronics

The DSMB-02C uses dedicated connectors to interface with the thyristor/diode modules. The associated maintenance documentation identifies six gate-control cables connecting the board to the power modules. Correct cable placement and connector seating are therefore important when the assembly is serviced.

The board also contains rectifier diode circuitry that can be checked during troubleshooting. These circuits are distinct from the main power stage and blower-inverter circuitry associated with the DSMB-01C. Understanding this distinction helps maintenance personnel identify the correct board and follow the relevant diagnostic procedure.

ABB Advant OCS Product Guide

ABB Advant OCS Product Guide

ABB Advant OCS Product Guide

ABB Advant OCS Product Guide


Automatic voltage control

Mvar control

The Mvar control mode is set automatically if the AVR fails. The voltage can be adjusted from central point of control by using the voltage up/down keys.

PF control

In the PF control mode the voltage/PF can be adjusted from central point of control by using the voltage up/down keys or by inserting a new value. The output setpoint is slowly changed to the new value. If the generator can not follow the setpoint, an audible alarm is created.

The output setpoint will be switched back to the actual value, and the program will try to reach the setpoint again. Reasons for not reaching the setpoint can be the excitor limits, or the generator is not connected with PPC or another generator, etc.

PF demand control

The PF demand control mode can only be activated if the generator is already in the PF control mode. The PF setpoint is now issued by the “Reactive Power Control” function, see also chapter 5.2. Before using this setpoint, the value must be valid. If the value is not valid within 10 minutes, an audible alarm is created.

An audible alarm is created and the AVR will return into the PF control mode if:

  • the PF setpoint value is not valid within 10 minutes
  • communication loss with the “Reactive Power Control”

The output setpoint into the PF demand control mode acts the same as in PF control mode.

ABB PFEA111-20 3BSE050090R20 | Processor module | PFEA112
ABB PM511V16 3BSE011181R1 | Programmable Logic Controller (PLC) Module
ABB PFSK152 3BSE018877R1 | Profinet IO Interface Module | PFSA240-A
ABB SR511 3BSE000863R0001 | Safety Relay Module | PSR60-600-70
ABB  XUD194 3BHE018137R0001 AC800PEC | Process automation controller
ABB HS810 3BDH000305R0101 | Safety PLC Module | 3HS2000-01
ABB AO2040 | Analog Output Module | AO3481
ABB DASO110 57120001-AT1 | Digital Output Module | DASA110 3ASC25H271
ABB  PFVO142 3BSE223732R0001 | valve positioner module | PFVO142  104884
ABB SUE3000 1VCR007346 G0032 | Safety controller module | PSU100
ABB SUE3000 1VCF750090R0804 | Servo Drive Module | SUE3000 1VCR007346 G0032
ABB  5SHX1960L0006 3BHB016120R0002 | High-VoltaGE  IGBT Module | 5SHX1960L0014
ABB  PP886 3BSE092980R1 | PLC Controller Module |  PP865 3BSE042236R1
ABB  SYN5302A-Z,V217 3BHB006716R0217 | Synchronization Module

 

 

mingpian mingpian mingpian mingpian mingpian