Description

ABB IGCT Module | ABB ACS6000 | ABB PCS6000

ABB IGCT Module | ABB ACS6000 | ABB PCS6000

ABB IGCT Module | ABB ACS6000 | ABB PCS6000

ABB IGCT Module | ABB ACS6000 | ABB PCS6000
$12,500.00
Brand model:ABB 5SHY4045L0001 (3BHB018162R0001)
Product Name:4500 V Asymmetric / Symmetric IGCT Power Module for ACS6000 & UNITROL 5000
Warranty: 1 year
Origin:Switzerland
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month
Warranty: 365 days
Payment method: T/T
Payment terms: 50% advance payment for futures; Full payment in cash for the stock
Phone: +86 18859254943
Email: sales@ygplc.com
WhatsApp: +86 18859254943ABB 5SHY4045L0001 (3BHB018162R0001) – 4500 V Asymmetric / Symmetric IGCT Power Module for ACS6000 & UNITROL 5000
5SHY4045L0001 is the type designation of the press-pack IGCT chip, and 3BHB018162R0001 is its corresponding order number; the two identify the same power module assembly. The module appears under two distinct technical descriptions across sources: an asymmetric IGCT (A-IGCT) with an integrated freewheeling diode, and a symmetric IGCT (S-IGCT) that blocks voltage bidirectionally without a separate diode. The asymmetry/symmetry classification, current rating, and peak current figures vary materially by source; the table preserves the divergent values with source context.
| Parameter | Specification |
|---|---|
| Device Type | Integrated Gate-Commutated Thyristor (IGCT), press-pack power semiconductor; cataloged as both Asymmetric IGCT and Symmetric IGCT (S-IGCT) depending on source framing |
| Model / Order Number | 5SHY4045L0001 (type); 3BHB018162R0001 (order code) |
| Repetitive Peak Off-State / Blocking Voltage (VDRM / VRRM) | 4500 V (consistent across all sources); symmetric variant blocks 4500 V in both forward and reverse directions (VDRM = VRRM) |
| Rated / Continuous On-State Current | 4000 A (most frequent catalog figure); some sources cite 3000 A RMS or 3120 A RMS as the rated on-state current depending on measurement basis and cooling condition |
| Maximum Turn-Off Current (ITGQM) | 4000 A (at VD ≈ 2800 V, Tj = 125 °C); alternate listings cite 8000 A peak turn-off / surge capability for the asymmetric variant |
| Surge Current (ITSM) | 28,000 A (10 ms, symmetric IGCT listing); asymmetric listing cites 8000 A non-repetitive peak |
| On-State Voltage Drop (VT) | ≈ 1.45 V (symmetric IGCT base value) to ≈ 1.8 V @ 4000 A (asymmetric IGCT listing); one source cites ≤ 1.5 V @ 3 kA |
| Switching Speed | Turn-on ≤ 2.5 μs; turn-off ≤ 6 μs (symmetric IGCT); asymmetric variant cited as ns-class / <1 μs switching |
| Switching Frequency | 1 kHz hard switching / 2 kHz soft switching (one source); 500 Hz – 2 kHz range in another; up to 1600 Hz in a third |
| Gate Drive Unit (GDU) | GVC750BE101 (order code 3BHE009681R0101), fiber-optic synchronized trigger with ±5 ns precision, 24 VDC supply, integrated overcurrent / overvoltage / overtemperature / short-circuit protection |
| Gate Drive Voltage | Typically ±15 V to ±20 V; minimum gate pulse current 10 mA |
| Cooling Method | Direct liquid cooling (deionized water/glycol), required flow 12–18 L/min to maintain ΔT < 6 °C; press-pack double-sided cooling |
| Junction Temperature | −40 °C to +125 °C (standard operating junction); one asymmetric listing cites max junction 175 °C |
| Package / Form Factor | Press-pack (StakPak / disc-type) ceramic housing; frame size 91 mm; approximate dimensions 178 × 127 × 36 mm to 220 × 140 × 80 mm depending on whether the assembly or bare disc is measured |
| Weight | ≈ 0.6 kg (bare IGCT disc) to 3.4 – 4 kg (full assembly / module with carrier and cooling interface) |
| Isolation / Communication | Fiber-optic gate command and status feedback from the converter controller (e.g., UFC912A101 control board); full galvanic isolation between gate drive and power circuit |
| Primary System Platforms | ACS6000 and ACS2000 medium-voltage drives; PCS6000 wind converters; STATCOM / FACTS; UNITROL 5000 excitation systems |
Note on the asymmetric vs. symmetric divergence: The same 5SHY4045L0001 / 3BHB018162R0001 identifier is positioned in two technical framings. Sources describing it as an asymmetric IGCT emphasize an integrated anti-parallel freewheeling diode, a 4000 A class turn-off current, and suitability for current-source inverter topologies. Sources describing it as a symmetric IGCT emphasize bidirectional 4500 V blocking (VDRM = VRRM), elimination of the freewheeling diode in four-quadrant regenerative drives, and a 28 kA surge rating. The 4500 V blocking voltage, press-pack construction, fiber-optic GDU interface, and ACS6000 / UNITROL platform association are consistent across both framings. Buyers should confirm the symmetric or asymmetric designation against the specific drive or excitation system serial configuration before replacement.