Description
ABB 5SHY35L4520 5SXE10-0181 AC10272001R0101 – 4,500 V Asymmetric IGCT Power Module with Matched Gate Driver Unit, Press-Pack Assembly for PCS6000 and Medium-Voltage Converters
| Parameter | Specification |
|---|---|
| Device Type | Asymmetric Integrated Gate-Commutated Thyristor (AS-IGCT) power module, supplied as a matched power-chip + gate-driver assembly |
| Market Model / Assembly Order Code | Power chip: 5SHY35L4520; matched gate driver board: 5SXE10-0181; complete assembly order code: AC10272001R0101 |
| Series / Platform | ABB 5SHY asymmetric IGCT series; PCS6000 medium-voltage water-cooled converter platform; also associated with ACS6000-class drive power stages in spare-parts listings |
| Repetitive Peak Off-State Voltage (V_DRM) | 4,500 V |
| DC Voltage Rating (V_DC) | 2,800 V |
| Controllable Peak Turn-Off Current (I_TGQM) | 4,000 A |
| Average On-State Current (I_TAVM) | 1,700 A per ABB device table; complete-assembly listings also cite 3,500 A I_TAV, reflecting different measurement bases or system-level ratings — confirm against the specific unit datasheet |
| Surge On-State Current (I_TSM) | 32 kA |
| On-State Voltage / Slope Resistance | Threshold voltage V_(T0) ≈ 1.4 V; slope resistance r_T ≈ 0.325 mΩ |
| Package / Mounting | Hockey-puck press-pack disc, case approximately Ø120.5 / Ø85 mm; clamp-mount into the converter stack with controlled clamping force (standard press force cited around 40 kN for the PCS6000 assembly) |
| Cooling Method | Water cooling, PCS6000 standard configuration; rated flow data in spare-parts listings cite approximately 15 L/min with inlet water ≤35 °C and outlet ≤55 °C |
| Switching Behaviour | Snubberless hard turn-off; turn-off time <5 μs in system-level descriptions; recommended operating switching frequency ≤1 kHz for medium-voltage drive and wind-converter duty |
| Gate Drive Interface | 5SXE10-0181 matched gate driver board provides turn-on / turn-off pulses, status feedback and short-circuit protection via fibre-optic command interface from the host controller |
| Insulation Class / Junction Temperature | Class H insulation; maximum allowable junction temperature T_jmax 125 °C |
| Protection Functions | Overvoltage, overcurrent, overtemperature, short-circuit and driver-supply undervoltage protection integrated at assembly level |
| Typical Applications | PCS6000 full-power wind converters, NPC three-level medium-voltage drives, VSC-HVDC, STATCOM and large industrial conversion systems |
Parameter note: The 5SHY35L4520 is consistently identified as an asymmetric IGCT without reverse-blocking capability, and the three identifiers form a matched set: 5SHY35L4520 is the power semiconductor die, 5SXE10-0181 is the dedicated gate driver board, and AC10272001R0101 is the complete assembly order code. Current ratings differ between the ABB device-level table (I_TAVM 1,700 A) and spare-parts/assembly listings (I_TAV 3,500 A); this spread typically arises from different cooling, pulse-duty or system-level conventions and should be resolved against the unit-specific datasheet for design-in or replacement purposes.

ABB IGCT Module | ABB ACS6000 | ABB PCS6000

ABB IGCT Module | ABB ACS6000 | ABB PCS6000